Guangdong Ruisite Electric Co., LTD.
Guangdong Ruisite Electric Co., LTD.
Products
100kw Portable Load Bank
  • 100kw Portable Load Bank100kw Portable Load Bank
  • 100kw Portable Load Bank100kw Portable Load Bank
  • 100kw Portable Load Bank100kw Portable Load Bank

100kw Portable Load Bank

RST Electric 100kW Portable Load Bank: a 100 kW resistive load bank for generator, UPS and switchgear testing. AC 230V/400V 50/60Hz, 1–48 kW load steps, ≤±3% step accuracy, ±0.5% V/A metering, continuous duty, IP20, 37 kg portable design. Wholesale and OEM orders welcome — contact RST Electric, China manufacturer/supplier.

    The RST 100kw Portable Load Bank is a 100 kW resistive load bank developed by Guangdong Ruisite Electric Co., Ltd. for commissioning, testing and maintenance of generators, UPS systems, inverters, switchgear and power distribution equipment. It provides a stable, controllable resistive load so that power sources can be verified under real load conditions rather than no-load settings.

    The unit accepts both AC 230 V single-phase and AC 400 V three-phase input at 50 Hz or 60 Hz, and loads all three phases simultaneously. Its resistive load steps are 1, 2, 3, 4, 6, 12, 24 and 48 kW, giving fine-grained selection with a load step accuracy of ≤ ±3%. Rated capacity is 100 kW with continuous-duty operation.

    What sets this load bank apart is the combination of portability and measurement quality. The whole system is housed in a compact indoor enclosure measuring 300 × 540 × 600 mm (W × D × H) and weighing approximately 37 kg, with casters mounted on the base for easy movement between test positions. Inside, a multifunction meter from Acrel and ABB A2X-series load contactors handle switching and measurement, while a local touchscreen plus remote communication provide flexible control.

    Measurement accuracy is ±0.5% for voltage, ±0.5% for current, ±0.1% for frequency, ±1% for power and ±1% for power factor. The operator can monitor current (I), voltage (V) and power (kW) in real time, with support for step loading and step unloading. Multiple units can be connected in parallel (1 + N) when higher test capacity is required.

    The enclosure is finished in RAL 7035 industrial gray and carries standard electrical-hazard, phase-sequence, screen-printed and nameplate labels. The illustration supplied with the proposal is for reference only; the final design is subject to approved drawings.

    Key Technical Specifications at a Glance


    Parameter Specification
    Model RST-100kW-AC400V-R
    Rated capacity 100 kW
    Rated voltage AC 230 V single-phase / AC 400 V three-phase
    Power frequency 50 Hz / 60 Hz
    Load type Resistive load
    Connection 200 A terminal block
    Load step accuracy ≤ ±3%
    Duty Continuous operation
    Control power supply AC 90–260 V, 50–60 Hz
    Power steps (resistive, kW) 1, 2, 3, 4, 6, 12, 24, 48
    Control method Local touchscreen + remote communication
    Cooling method Forced-air cooling (side inlet, side outlet)
    Insulation class Class F
    Measurement accuracy Voltage ±0.5%; current ±0.5%; frequency ±0.1%; power ±1%; power factor ±1%
    Ambient temperature -20°C to +55°C
    Operating altitude Below 1,500 m
    Relative humidity Less than 95%
    Atmospheric pressure 86–106 kPa
    Enclosure dimensions 300 × 540 × 600 mm (W × D × H)
    Weight Approx. 37 kg (for reference)
    Ingress protection IP20
    Installation location Indoor
    Load expansion 1 + N load banks in parallel

    RST-100kW portable AC load bank — product illustration for reference only; final design is subject to the approved drawings.


    Operation and Daily Maintenance: Keeping the Load Bank Accurate and Safe

    A load bank converts electrical energy into heat, so correct operation and routine care directly affect both measurement accuracy and service life.


    Before Each Test


    • Confirm the unit is installed indoors on a stable surface with unobstructed side air inlet and outlet.
    • Check the 200 A terminal block and all power cables for tight, correct connections.
    • Verify the control power supply is within AC 90–260 V, 50–60 Hz.
    • Start the cooling fan first. The load can be applied only after the fan has started (fan interlock protection).
    • Set the required load step on the touchscreen and confirm the three phases are loading simultaneously.


    Safe Operating Practices


    • Never apply load with the emergency stop latched; loading is disabled while it is engaged.
    • Do not block the air inlet or outlet; restricted airflow raises internal temperature quickly.
    • Keep flammable materials away from the enclosure and observe the electrical-hazard markings.
    • Operate within the rated envelope: ambient -20°C to +55°C, altitude below 1,500 m, humidity below 95%.
    • Monitor real-time voltage, current and power on the meter; stop the test if readings exceed safe limits.


    Routine Maintenance Essentials


    • Periodically inspect terminals and cables for looseness, ageing or damage, and tighten as required.
    • Clean dust from the resistor section, fans and air passages with compressed air to preserve cooling performance.
    • Check that all temperature sensors and the mechanical over-temperature protection operate correctly.
    • Inspect fans for abnormal noise or reduced airflow and replace when necessary.
    • After maintenance, confirm the meter, touchscreen and remote communication still display and report correctly.


    Protection Functions You Can Rely On


    • Overvoltage protection: the threshold is set on the power meter; if input voltage exceeds the safe limit, the load is automatically disconnected and an alarm is triggered.
    • Emergency stop: one manual action forcibly disconnects the load; loading stays disabled while latched, while fan control and operating supply remain intact.
    • Over-temperature protection: mechanical temperature sensors monitor each load module; if temperature exceeds the safe limit, the load is disconnected and an alarm is triggered.
    • Fan interlock protection: load can be applied only after the cooling fan has started.



    Key operating rule: always start the cooling fan before applying load, and keep the air inlet and outlet fully clear throughout the test.


    Frequently Asked Questions

    Q1: What is a portable AC load bank and why is it needed?

    A: A portable AC load bank applies a controlled electrical load to a power source so its performance can be verified under real working conditions. Instead of running a generator, UPS or inverter at no load, the RST-100kW-AC400V-R draws up to 100 kW of resistive power, allowing you to confirm voltage regulation, frequency stability, capacity and protection behavior before the equipment enters service.


    Q2: What equipment can the RST 100kw Portable Load Bank?

    A: It is designed for commissioning and routine testing of generators, UPS systems, inverters, switchgear, power distribution cabinets and similar AC power equipment. It accepts AC 230 V single-phase or AC 400 V three-phase supply at 50/60 Hz and loads all three phases simultaneously.


    Q3: How fine is the load adjustment, and can it run continuously?

    A: The resistive load steps are 1, 2, 3, 4, 6, 12, 24 and 48 kW with step accuracy of ≤ ±3%. It supports step loading and step unloading and is rated for continuous operation, so it suits both quick acceptance checks and long-duration load tests.


    Q4: How accurate are the measurements?

    A: The multifunction meter provides voltage and current accuracy of ±0.5%, frequency ±0.1%, power ±1% and power factor ±1%. Current, voltage and power are displayed in real time on the local meter and touchscreen for immediate verification.


    Q5: What happens if the unit overheats or the input voltage is too high?

    A: Mechanical temperature sensors monitor each load module, and the power meter monitors input voltage. If either exceeds its safe limit, the load is automatically disconnected and an alarm is triggered. The emergency stop provides an additional one-action manual disconnect.


    Q6: Can multiple load banks be used together?

    A: Yes. The design supports 1 + N parallel connection of load banks when the required test capacity exceeds a single 100 kW unit. Casters on the base allow individual units to be positioned quickly.


    Q7: Can the load bank be used outdoors or in harsh environments?

    A: It is an indoor unit with IP20 protection. The specified operating range is ambient -20°C to +55°C, altitude below 1,500 m, relative humidity below 95% and atmospheric pressure 86–106 kPa. For outdoor or wet-location testing, use a suitable protected enclosure.


    Real-world Application Scenarios

    Scenario 1: Generator Commissioning and Load Acceptance Testing


    A generator set must be proven under load before it is accepted or handed over to a customer. Using the RST-100kW-AC400V-R, technicians apply the 1–48 kW load steps in sequence up to the full 100 kW rating while watching voltage, frequency and power on the meter.


    The ≤ ±3% step accuracy and ±1% power measurement make the acceptance data credible, and continuous-duty operation allows a sustained load run. The emergency stop and overvoltage protection safeguard both the generator and the load bank during unstable startup.


    Scenario 2: UPS and Inverter Capacity Verification


    Data rooms and critical power installations depend on UPS and inverter systems that must be verified at realistic load levels. The load bank's single-phase 230 V and three-phase 400 V inputs, together with simultaneous three-phase loading, let engineers test both small single-phase units and larger three-phase systems. Real-time display of current, voltage and power plus remote communication allow test data to be observed and recorded from a safe distance.


    Scenario 3: Switchgear and Distribution Cabinet Testing


    Power distribution cabinets and switchgear need verification of phase sequence, breaker behavior and thermal performance under load. The enclosure's phase-sequence and electrical-hazard labeling supports safe connection, while the ABB contactors and CHINT/ABB auxiliary components provide reliable switching. Step loading and unloading let technicians reproduce different operating conditions without rewiring.


    Scenario 4: Scaled Testing with Parallel Load Banks


    When a test requires more than 100 kW, multiple RST-100kW-AC400V-R units can be connected in parallel (1 + N). Each unit's casters allow quick positioning, and forced-air cooling with side inlet and outlet keeps each cabinet within its thermal envelope during extended tests.


    Customer feedback: users value the portable enclosure, straightforward touchscreen operation and dependable protection functions. The combination of fine load steps and clear measurement display reduces test setup time and gives commissioning teams confidence in the results.


    Summary of Product Advantages

    1.Accurate, flexible loading — 100 kW capacity with load steps of 1, 2, 3, 4, 6, 12, 24 and 48 kW and ≤ ±3% step accuracy, covering both fine and full-load testing.


    2.High measurement confidence — voltage and current at ±0.5%, frequency ±0.1%, power ±1% and power factor ±1%, with real-time display of I, V and kW.


    3.Portable and compact — 300 × 540 × 600 mm enclosure, approximately 37 kg, with base casters for easy movement; RAL 7035 industrial gray finish.


    4.Complete protection — overvoltage, over-temperature, emergency stop and fan interlock protection with automatic load disconnect and alarms.


    5.Reliable components — Acrel multifunction meter, ABB A2X-series contactors and CHINT/ABB auxiliary components selected for stable, long-term operation.


    6.Continuous duty and scalability — rated for continuous operation with 1 + N parallel expansion for higher-capacity tests.


    Send Inquiry
    Contact Info
    If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept